This comprehensive guide serves as your definitive resource for understanding and utilizing the Linear AP-5 Wireless Access Controller. Explore its features, installation, programming, and troubleshooting. Benefit from the insights and instructions provided, maximizing the potential of your AP-5 system.

Overview of the Linear AP-5 Wireless Access Controller

The Linear AP-5 Wireless Access Controller is a versatile device designed for controlling access points, such as door strikes and mag-locks. It operates on a high-gain superheterodyne UHF receiver, ensuring reliable performance and extended range, up to 500 feet with an external antenna. This controller supports a large number of transmitters, accommodating up to 480 Linear MegaCode or block-coded transmitters, making it suitable for various applications.

Ideal for gated communities, parking facilities, and industrial sites, the AP-5 simplifies access management. Its multi-purpose design allows it to manage one or two doors or gates, enhancing its flexibility. The controller also provides manual activation options via OPEN and number keys for relay control, specifically K1 and K2. This feature enables immediate operation, offering an alternative to transmitter-based access.

Furthermore, the AP-5’s compatibility with Linear radio controls ensures a reliable and secure access system. This controller is engineered to meet the demands of modern access control, providing a robust and user-friendly solution for diverse security needs.

Applications of the AP-5: Door Strikes, Mag-Locks, and Gates

The Linear AP-5 Wireless Access Controller excels in various access control scenarios, particularly with door strikes, mag-locks, and gates. For door strikes, the AP-5 provides a seamless wireless activation, enhancing security and convenience in commercial and residential buildings. Its compatibility with mag-locks makes it suitable for high-security entrances, ensuring controlled access while eliminating the need for physical keys.

In gated communities and parking facilities, the AP-5 manages gate access effectively. Residents or authorized personnel can easily open gates using compatible transmitters, improving traffic flow and security. The system’s ability to support up to 480 transmitters makes it ideal for locations with numerous users.

Furthermore, the AP-5 is applicable in industrial settings for controlling access to restricted areas or equipment. The manual activation feature, using OPEN and number keys for relay control, allows for immediate access in specific situations. Overall, the AP-5’s versatility makes it a reliable solution for diverse access control needs, ensuring security and ease of use.

Installation Instructions

Follow these detailed instructions for proper AP-5 installation. Ensure correct wiring and connections for reliable operation. Optimize antenna placement to achieve the maximum 500-foot range. Proper installation is crucial for optimal performance.

Wiring and Connections Guide

This guide provides detailed instructions for wiring the Linear AP-5 Wireless Access Controller. Correct wiring is essential for reliable performance. Ensure power is disconnected before beginning any wiring work. Identify the appropriate terminals for power input, relay outputs (K1 and K2), and antenna connection. Use properly sized wiring for all connections.

For door strike or mag-lock applications, connect the relay outputs to the appropriate device. Refer to the device’s manual for specific wiring instructions. Double-check all connections before applying power. Improper wiring can damage the AP-5 or connected devices.

The AP-5 utilizes a superheterodyne UHF receiver, so ensure the antenna is properly connected to the designated terminal. A secure antenna connection is crucial for optimal range and reliable signal reception. Follow all local and national electrical codes during installation.

Pay close attention to polarity when connecting power. Reverse polarity can damage the unit. If you are unsure about any aspect of the wiring process, consult a qualified electrician or Linear Technical Services.

Antenna Placement for Optimal Range (Up to 500 Feet)

Optimal antenna placement is crucial to achieving the AP-5’s maximum range of up to 500 feet. The antenna should be mounted in a location that provides a clear line of sight to the transmitters. Avoid obstructions such as walls, trees, and metal structures, as these can significantly reduce range.

Mount the antenna as high as possible to maximize its coverage area. Consider using an external antenna for improved performance, especially in environments with significant interference or obstructions. Ensure the antenna is securely mounted to prevent damage from wind or other environmental factors.

Experiment with different antenna positions to find the optimal location. Use a signal strength meter to measure the signal strength at various locations. Keep the antenna cable as short as possible to minimize signal loss. Avoid running the antenna cable near sources of electrical interference.

Regularly inspect the antenna and cable for damage. Replace any damaged components immediately. Proper antenna placement will ensure reliable and consistent performance of your Linear AP-5 system.

Programming and Operation

This section details the procedures for programming transmitters and operating the Linear AP-5. Learn how to program up to 480 transmitters and utilize manual activation for relay control, ensuring seamless access management.

Transmitter Compatibility: MegaCode and Block Coded Transmitters

The Linear AP-5 Wireless Access Controller exhibits versatile compatibility with a range of transmitter types, primarily focusing on MegaCode and block coded transmitters. This feature allows for integration with existing access control systems, streamlining the upgrade process and minimizing the need for complete system overhauls. MegaCode transmitters, known for their enhanced security features and rolling code technology, provide a robust solution against unauthorized access. The rolling code mechanism ensures that each transmission is unique, preventing replay attacks and enhancing overall system security.

Furthermore, the AP-5 supports block coded transmitters, offering a cost-effective alternative for applications where advanced security features are not paramount; Block coded transmitters utilize a fixed code, simplifying the programming process and reducing the complexity of system management. The compatibility with both MegaCode and block coded transmitters provides flexibility in selecting the appropriate transmitter type based on specific security requirements and budget constraints. This dual compatibility makes the Linear AP-5 a versatile and adaptable solution for a wide range of access control applications, catering to diverse needs and preferences.

Programming up to 480 Transmitters

The Linear AP-5 Wireless Access Controller boasts a substantial memory capacity, enabling the programming of up to 480 transmitters. This extensive capacity makes the AP-5 ideal for applications requiring support for a large number of users, such as gated communities, parking facilities, and industrial sites. The programming process is designed to be user-friendly, allowing for efficient and straightforward addition or removal of transmitters from the system. This capability streamlines system management and reduces administrative overhead.

The ability to program a large number of transmitters ensures scalability, accommodating future growth and expansion without requiring significant hardware upgrades. This feature enhances the long-term value of the AP-5, making it a worthwhile investment for organizations with evolving access control needs. Whether managing access for residents, employees, or visitors, the AP-5 provides the flexibility and capacity to handle diverse access control requirements. This high transmitter capacity, coupled with user-friendly programming, positions the Linear AP-5 as a robust and adaptable solution for a wide range of applications;

Manual Activation: Using OPEN and Number Keys for Relay Control (K1, K2)

The Linear AP-5 provides a convenient manual activation feature, allowing direct control of the relays (K1 and K2) without relying solely on programmed transmitters. This is achieved through a simple sequence using the “OPEN” button and the number keys. Pressing the “OPEN” button followed by the “1” key will activate relay K1. Similarly, pressing the “OPEN” button followed by the “2” key will activate relay K2. This manual activation method offers a straightforward way to trigger connected devices, such as door strikes or gate operators, directly from the AP-5 unit.

This functionality can be particularly useful for testing purposes, temporary access control, or situations where a transmitter is unavailable; The clear and intuitive sequence makes it easy for authorized personnel to manually operate the system. Each relay will remain active for a predetermined duration, as configured within the AP-5’s settings. This manual override capability adds another layer of flexibility to the AP-5 system, ensuring continued operation even in unforeseen circumstances. The simplicity of the process makes it accessible to users with varying levels of technical expertise.

Troubleshooting

Encountering issues with your Linear AP-5? This section provides guidance on diagnosing and resolving common problems. Refer to the solutions outlined to address connectivity, transmitter recognition, and relay activation failures, ensuring smooth operation.

Common Issues and Solutions

This section addresses frequent problems encountered with the Linear AP-5 Wireless Access Controller and offers practical solutions. One common issue is range limitations. Ensure the antenna is properly placed and unobstructed for optimal performance, potentially reaching up to 500 feet. Interference from other devices can also impact range; try relocating the antenna.

Another frequent concern involves transmitter compatibility. The AP-5 supports MegaCode and Block Coded transmitters. Verify that your transmitters are compatible and correctly programmed. Up to 480 transmitters can be programmed. If transmitters are not recognized, double-check the programming procedure, ensuring the correct sequence and codes are entered.

Relay activation failures may occur due to wiring errors or faulty relays. Inspect the wiring connections to the door strikes, mag-locks, or gates. Use the OPEN and number keys (1 or 2) for manual activation of relays K1 and K2, respectively. For further assistance, contact Linear Technical Services at 1-800-421-1587.

Contacting Linear Technical Services

For support and RPA (Return Product Authorization) information regarding your Linear AP-5 Wireless Access Controller, please contact Linear Technical Services. You can reach them by calling 1-800-421-1587 for expert assistance.

Support and RPA Information (1-800-421-1587)

If you require assistance with your Linear AP-5 Wireless Access Controller, Linear Technical Services is available to provide comprehensive support. Their experienced technicians can assist with troubleshooting, programming questions, and any other technical inquiries you may have. Before contacting them, please have your model number and a detailed description of the issue ready to expedite the support process.

In the event that your AP-5 unit requires repair or replacement, you will need to obtain an RPA (Return Product Authorization) number. This number is essential for processing any returns and ensuring proper tracking of your unit. To obtain an RPA, contact Linear Technical Services at 1-800-421-1587. Be prepared to provide the unit’s serial number, proof of purchase, and a clear explanation of the reason for the return.

Please note that Linear’s warranty policy applies to all returns, and certain conditions may need to be met for warranty coverage. Linear Technical Services can provide you with detailed information regarding the warranty terms and conditions applicable to your AP-5 Wireless Access Controller.